cropped-LP-LogoSymbolOnly-Color-011723.webpMENU

433

The parts were marked using a 20 Watt Pulsed Fiber Laser using a 160 mm lens. The samples were ablated using 9 watts of power, with the frequency of 20 kHz, speed of 20″ per second, resulting in a cycle time of 0.25 second for the scale marking, 0.92 second for...

432

This part was marked using a 20 watt q-switched ytterbium fiber laser with a 160 mm focal length lens. The sample was surface etched, to create the light marks on the part. Samples were marked with process parameters to cause the least amount of damage to the surface...

428