cropped-LP-LogoSymbolOnly-Color-011723.webpMENU

503

This application was done with a low power system in the lab. The recommendation for this process, for the grey bulk molding compound, would be for a minimum of 100watt laser for projected cutting speeds of 1mm per second. Preferred system would be a 200watt laser...

521

The part was marked using a 20 Watt Pulsed Fiber Laser System using a 160 mm lens. The canister was marked with the same parameters for a light etched mark. The part was marked with a character height of 0.65”. The characters had a cycle time of 1.38...

556

The samples were marked using a 20 watt Q-switched Fiber Laser using a 160 mm lens. The Colt logo (vector graphic) was annealed using 15 Watts of power, frequency of 80 kHz, speed of 5″ per second, resulting in a cycle time of 8.65 seconds. The FBI logo (raster...

574

The scissor blades were marked using a 20 watt q-switched ytterbium fiber laser, along with a 160mm focal length lens. The blades were marked with a dark surface mark. Each mark was made with the intention of keeping the cycle at or below 4 seconds. The blades were...

590

The part was marked using a 20Watt Fiber Laser Marking System using a 160 mm lens.  The cycle times for the part was below one second.